Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 138

Advertising
background image

Publication 1398-5.0 – October 1998

8-14

Application and Configuration Examples

5. Verify the communications port settings of the PC match those of

the drive.

• If the settings are correct, select

OK

in the Port – Settings dia-

log box.

• If the settings are different, correct the Port – Settings to allow

communications with the drive.

Factory default communications Port – Settings for the drive
are:

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to the section “RS-232 Communication Test” on page 11-11
for troubleshooting instructions.

6. Select

R

ead Drive Parameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that

is being addressed.

8. Choose

OK

to load the drive parameters.

9. If the message box appears that a motor must be selected, select

OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

,

12. Select

Follower: Master

E

ncoder

as the Operation Mode for the

drive.

13. Choose

Close

from the Drive Setup window.

14. Choose the

Drive

P

arameter

command icon from the Drive win-

dow, then select the

Follower

tab.

15. Enter an appropriate

G

ear Ratio

as the Follower Input. The

default Gear Ratio is 1:1 (motor encoder pulses:master pulses). If
a Gear Ratio of 3:1 is entered, the motor is moved 3 encoder
pulses for every incoming master pulse.

Note: A motor must be selected for the parameters to load.

Advertising