Drive output connected to active low input using, A switch/relay, An opto-isolator – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual
Page 77
Advertising
Publication 1398-5.0 – October 1998
Interfaces
6-13
Figure 6.14
Drive Output Connected to Active Low Input using
a Switch/Relay
Intro
Figure 6.15
Drive Output Connected to Active Low Input using
an Opto-Isolator
Intro
Figure 6.16
Drive Output Connected to Active High (Sinking) Input
Intro
Solid State
Relay
(Drive)
24VCOM
24VCOM
3.3K
+24VDC
+24VDC
INPUT
OUTPUT
24VCOM
+24VDC
1K
24VCOM
+24VDC
3.3 K
INPUT
OUTPUT
(Drive)
24VCOM
+24VDC
INPUT
OUTPUT
(Drive)
24VCOM
J1-6 or J1-13
1K