Drive output connected to active low input using, A switch/relay, An opto-isolator – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 77

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-13

Figure 6.14

Drive Output Connected to Active Low Input using
a Switch/Relay

Intro

Figure 6.15

Drive Output Connected to Active Low Input using
an Opto-Isolator

Intro

Figure 6.16

Drive Output Connected to Active High (Sinking) Input

Intro

Solid State

Relay

(Drive)

24VCOM

24VCOM

3.3K

+24VDC

+24VDC

INPUT

OUTPUT

24VCOM

+24VDC

1K

24VCOM

+24VDC

3.3 K

INPUT

OUTPUT

(Drive)

24VCOM

+24VDC

INPUT

OUTPUT

(Drive)

24VCOM

J1-6 or J1-13

1K

Advertising