Publication 1398-5.0 – October 1998

8-2

Application and Configuration Examples

5. Connect a jumper wire with a toggle switch between the follow-

ing pins:

• J1-20 (ENABLE) and J1-26 (I/O PWR)

• J1-21 (FAULT RESET) and J1-26 (I/O PWR).

These connections provide manual control for enabling or
disabling the drive and resetting faults. The figure below shows
the jumper, including normally open toggle switches.

6. Connect the drive to a 100/240 VAC, 50/60 Hz power source

appropriate to the drive:

• Single Phase: 1398-DDM-010, 1398-DDM-010X,

1398-DDM-020, 1398-DDM-020X, 1398-DDM-030,
1398-DDM-030X, 1398-DDM-075 or 1398-DDM-075X

• Three Phase: 1398-DDM-075, 1398-DDM-075X,

1398-DDM-150 or 1398-DDM-150X

Connection Diagram

Figure 8.1

Analog Controller Connection Diagram

Intro

J1

26 +24V

20 ENABLE

21 FAULT

22 CMND+

23 CMND-

Close to ENABLE Drive

Close to RESET Fault

±10 VDC

DRIVE

TB1

L1

L2/N

Gnd

L1

L2/N

Gnd

100-240 VAC

50/60 Hz

Three Phase

Power Source

L3

or

100-240 VAC

50/60 Hz

Single Phase

Power Source

TB1

RESET

J4

2 RCV

3 XMT

5 COM

XMT

RCV

COM

TB1

Phase R 1

Phase S 2

Phase T 3

Motor Gnd 4

J2

Motor
Encoder