Application and Configuration Examples
8. Open the switch between J1-26 and J1-20 to disable the drive.
9. Choose
C
lose
to exit the Tuning window.
10. Close any open windows or dialog boxes.
Operation
The drive is now configured as either a Position Follower (Step Up/
Step Down).
●
The servo parameters have been setup with the unloaded motor.
●
The motor position is controlled by the step indexer.
The firmware saves the parameters in EEPROM memory. Thus the
drive can be power cycled and, after power-up, will use the
parameters selected in the steps above.
When motion is required:
1. Close the switch between J1-26 and J1-20 to enable the drive.
2. Close the toggle switch between J1-26 and J1-32 to enable fol-
lowing.