Publication 1398-5.0 – October 1998

8-26

Application and Configuration Examples

8. Open the switch between J1-26 and J1-20 to disable the drive.

9. Choose

C

lose

to exit the Tuning window.

10. Close any open windows or dialog boxes.

Operation

The drive is now configured as either a Position Follower (Step Up/
Step Down).

The servo parameters have been setup with the unloaded motor.

The motor position is controlled by the step indexer.

The firmware saves the parameters in EEPROM memory. Thus the
drive can be power cycled and, after power-up, will use the
parameters selected in the steps above.

When motion is required:

1. Close the switch between J1-26 and J1-20 to enable the drive.

2. Close the toggle switch between J1-26 and J1-32 to enable fol-

lowing.