Operation – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 162

Advertising
background image

Publication 1398-5.0 – October 1998

8-38

Application and Configuration Examples

5. Close the toggle switch between J1-26 and J1-20 to enable the

drive.

6. Choose

S

tart

from the Tuning window. The drive powers the

motor shaft for a short period and then motion will cease. Then
ULTRA Master displays the calculated gains and disables the
drive.

7. Choose

N

ormal Drive Operation

from the Tuning window.

8. Open the switch between J1-26 and J1-20 to disable the drive.

9. Choose

C

lose

to exit the Tuning window.

10. Close any open windows or dialog boxes.

Operation

The drive is now configured as a Registration Indexing controller.

The servo parameters have been setup with the unloaded motor.

Motion is commanded through the inputs.

The firmware saves the parameters in EEPROM memory. Thus the
drive can be power cycled and, after power-up, will use the
parameters selected in the steps above.

When motion is required:

1. Close the switch between J1-26 and J1-20 to enable the drive.

2. Close the toggle switch between J1-26 and J1-32 to start Index 0.

3. Close the toggle switch between J1-26 and J1-33 to simulate reg-

istration.

!

Intro

ATTENTION: Rotating motor shafts can cause extensive
damage and injury. Motors must be properly guarded dur-
ing testing and installation.

Advertising