The following characters are permitted in the
Name
column of the tool table: # $ % & , - . 0 1 2 3 4 5 6 7
8 9 @ A B C D E F G H I J K L M N O P Q R S T U V
W X Y Z _
The TNC changes a comma in the tool name to a
period during import.
The TNC overwrites the selected tool table when
running the
IMPORT TABLE function. To avoid losing
data, be sure to make a backup copy of your original
tool table before importing it!
The procedure for copying tool tables using the
TNC file manager is described in the section on file
management (see "Copying a table", page 117).
When tool tables are imported from an iTNC 530,
all existing tools are imported along with their
corresponding tool type. Nonexistent tool types are
imported as type 0 (MILL). Check the tool table after