Checking and changing q parameters 9.7 – HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual

Page 301

Advertising
background image

Checking and changing Q parameters

9.7

9

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

301

You can have the Q parameters be shown in the additional status
display in all operating modes (except for the

Programming

operating mode).

If you are in a program run, interrupt it if required (for example,

by pressing the machine STOP button and the soft key). If you

are in a test run, interrupt it.

Call the soft-key row for screen layout

Select the screen layout with additional status

display: In the right half of the screen, the TNC
shows the

Overview status form

Press the

STATUS OF Q PARAM. soft key

Press the

Q PARAMETER LIST soft key: The TNC

opens a pop-up window
For each parameter type (Q, QL, QR, QS), define

the parameter numbers you wish to control.

Separate single Q parameters with a comma, and

connect sequential Q parameters with a hyphen,

e.g. 1,3,200-208. The input range per parameter

type is 132 characters.

The display in the

QPARA tab always contains eight

decimal places. The result of Q1 = COS89.999 is

shown by the control as 0.00001745 for example.

Very large or very small values are displayed by

the control in exponential notation. The result of

Q1 = COS 89.999 * 0.001 is shown by the control as

+1.74532925e-08, whereby e-08 corresponds to the

factor of 10

-8

.