Functions of the TNC 620 and the iTNC 530 compared

18.5

18

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

611

Comparison: Differences in Manual Operation,
operation

Function

TNC 620

iTNC 530

Capturing the position values from

mechanical probes

Actual-position capture by soft key

Actual-position capture by hard key

Exiting the touch probe functions

menu

Only via the

END soft key

Via the

END soft key or the END

hard key

Comparison: Differences in Program Run, operation

Function

TNC 620

iTNC 530

Arrangement of soft-key rows and

soft keys within the rows

Arrangement of soft-key rows and soft-keys varies depending on the

active screen layout.

Operating-mode switchover after

program run was interrupted by

switching to the Single Block

mode of operation, and canceled
by

INTERNAL STOP

When you return to the Program

Run mode of operation: Error
message

Selected block not

addressed. Use mid-program

startup to select the point of

interruption

Switching the operating mode

is allowed, modal information

is saved, program run can be

continued by pressing NC start

GOTO is used to go to FK

sequences after program run was

interrupted there before switching

the operating mode

Error message

FK programming:

Undefined starting position

GOTO allowed

Entering with

GOTO in the

Program run single block

Function is only possible if the NC

program was not yet started or
after pressing the

INTERNAL STOP

soft key

INTERNAL STOP

Function also possible after

starting the NC program

Mid-program startup:

Behavior after restoring the

machine status

The menu for returning must
be selected with the

RESTORE

POSITION soft key

Menu for returning is selected

automatically

Completing positioning for mid-

program startup

After position has been

reached, positioning mode

must be exited with the

RESTORE POSITION soft key

The positioning mode is

automatically exited after the

position has been reached

Switching the screen layout for

mid-program startup

Only possible, if startup

position has already been

approached

Possible in all operating states

Error messages

Error messages are still active

after the error has been corrected

and must be acknowledged

separately

Error messages are sometimes

acknowledged automatically after

the error has been corrected

Point patterns in single block

With point pattern cycles and

CYCL CALL PAT, the control stops

after each point.

Point pattern cycles and

CYCL

CALL PAT are handled by the

control as a single block