background image

Optional safety concept (functional safety FS) 14.4

14

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

447

14.4

Optional safety concept (functional
safety FS)

Miscellaneous

You machine tool builder adapts the HEIDENHAIN

safety concept to your machine. Refer to your

machine manual.

Every machine tool operator is exposed to certain risks. Although

protective devices can prevent access to dangerous points, the

operator must also be able to work on the machine without this

protection (e.g. protective door opened). Several guidelines and

regulations to minimize these risks have been developed within the

last few years.
The HEIDENHAIN safety concept integrated in the TNC controls

complies with

Performance Level d

as per EN 13849-1 and SIL

2 as per IEC 61508, features safety-related modes of operation

in accordance with EN 12417, and assures extensive operator

protection.
The basis of the HEIDENHAIN safety concept is the dual-channel

processor structure, which consists of the main computer (MC)

and one or more drive controller modules (CC= control computing

unit). All monitoring mechanisms are designed redundantly in

the control systems. Safety-relevant system data are subject to a

mutual cyclic data comparison. Safety-relevant errors always lead to

safe stopping of all drives through defined stop reactions.
Defined safety functions are triggered and safe operating statuses

are achieved via safety-relevant inputs and outputs (dual-channel

implementation), which have an influence on the system in all

operating modes.
In this chapter you will find explanations of the functions that are

additionally available on a TNC with functional safety.