1 switch-on, switch-off, Switch-on, Switch-on, switch-off – HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual

Page 430

Advertising
background image

Manual operation and setup

14.1 Switch-on, switch-off

14

430

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

14.1

Switch-on, switch-off

Switch-on

Switch-on and crossing over the reference points can

vary depending on the machine tool.
Refer to your machine manual.

Switch on the power supply for TNC and machine. The TNC then

displays the following dialog:
SYSTEM STARTUP

TNC is started

POWER INTERRUPTED

TNC message that the power was interrupted—

clear the message

COMPILE A PLC PROGRAM

The PLC program of the TNC is automatically compiled

RELAY EXT. DC VOLTAGE MISSING

Switch on external dc voltage. The TNC checks the

functioning of the EMERGENCY STOP circuit

MANUAL OPERATION

TRAVERSE REFERENCE POINTS

Cross the reference points manually in the

displayed sequence: For each axis press the

machine START button, or
Cross the reference points in any sequence: Press

and hold the machine axis direction button for each

axis until the reference point has been traversed

If your machine is equipped with absolute encoders,

you can leave out crossing the reference marks.

In such a case, the TNC is ready for operation

immediately after the machine control voltage is

switched on.

The TNC is now ready for operation in the

Manual Operation

mode.

The reference points need only be crossed if the

machine axes are to be moved. If you intend only

to write, edit or test programs, you can select
the

Programming or Test Run mode of operation

immediately after switching on the control voltage.
You can cross the reference points later by pressing
the

PASS OVER REFERENCE soft key in the MANUAL

OPERATION mode.