Manual operation and setup

14.5 Datum management with the preset table

14

456

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

Overwrite protection for datum

The line 0 in the preset table is write protected. The TNC saves the

last manually set datum in line 0.
You can overwrite-protect further lines in the preset table with
the

LOCKED column. The overwrite-protected lines are color-

highlighted in the preset table.

Caution: Data may be lost!

If you forget the password, you can no longer reset

the write-protection of a password-protected line.
Make note of the password when you password-

protect lines.
Preferentially use simple protection with the soft

key.

Proceed as follows to protect a datum from overwriting:

Press the

CHANGE PRESET soft key

Select the

LOCKED column

Press the

EDIT CURRENT FIELD soft key

Protection for datum without using password:

Press the soft key. The TNC writes an

L in the

LOCKED column.

Protection for datum with password:

Press the soft key

Enter the password into the pop-up window
Confirm with the

OK soft key or the ENT key: The

TNC writes

### in the LOCKED column.