Manual operation and setup

14.8 Calibrating a 3-D touch trigger probe (option 17)

14

470

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

Calibrating the effective radius and compensating
center misalignment

HEIDENHAIN only gives warranty for the function of

the probing cycles if HEIDENHAIN touch probes are

used.

The center offset can be determined only with a

suitable touch probe.
If you want to calibrate using the outside of an

object, you need to preposition the touch probe

above the center of the calibration sphere or

calibration pin. Ensure that the touch points can be

approached without collision.

When calibrating the ball tip radius, the TNC executes an automatic

probing routine. During the first probing cycle, the TNC determines

the center of the calibration ring or stud (coarse measurement)

and positions the touch probe in the center. Then the ball tip

radius is determined during the actual calibration process (fine

measurement). If the touch probe allows probing from opposite

orientations, the center offset is determined during another cycle.
The characteristic of whether and how your touch probe can be

oriented is already defined in HEIDENHAIN touch probes. Other

touch probes are configured by the machine tool builder.
After the touch probe is inserted, it normally needs to be aligned

exactly with the spindle axis. The calibration function can

determine the offset between touch-probe axis and spindle axis

by probing from opposite orientations (rotation by 180°) and can

compute the compensation.
The calibration routine varies depending on how your touch probe

can be oriented:

No orientation possible or orientation possible in only one

direction: The TNC executes one approximate and one fine

measurement and determines the effective ball tip radius

(column R in tool.t)
Orientation possible in two directions (e.g.. HEIDENHAIN touch

probes with cable): The TNC executes one approximate and

one fine measurement, rotates the touch probe by 180° and

then executes one more probing operation. The center offset

(CAL_OF in tchprobe.tp) is determined in addition to the radius

by probing from opposite orientations.
Any orientation possible (e.g. HEIDENHAIN infrared touch

probes): For probing routine, see "orientation possible in two

directions."