Additional functions 9.8 – HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual

Page 307

Advertising
background image

Additional functions

9.8

9

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

307

D16 – Formatted output of text and Q parameter
values

With

D16, you can also output to the screen any

messages from the NC program. Such messages are

displayed by the TNC in a pop-up window.

The function

D16 transfers Q parameter values and texts in a

selectable format. If you send the values, the TNC saves the data
in the file that you defined in the

D16 block. The maximum size of

the output file is 20 kilobytes.
To output the formatted texts and Q-parameter values, create a

text file with the TNC’s text editor. In this file you then define the

output format and Q parameters you want to output.
Example of a text file to define the output format:
"MEASURING LOG OF IMPELLER CENTER OF GRAVITY";
"DATUM: %02d.%02d.%04d",DAY,MONTH,YEAR4;
"TIME: %02d:%02d:%02d",HOUR,MIN,SEC;
"NO. OF MEASURED VALUES: = 1";
“X1 = %9.3LF“, Q31;
“Y1 = %9.3LF“, Q32;
"Z1 = %9.3LF", Q33;
When you create a text file, use the following formatting functions:

Special
characters

Function

"..........."

Define output format for texts and variables

between the quotation marks

%9.3LF

Define the format for Q parameters: 9 total

characters (incl. decimal point), of which 3

are after the decimal, Long, Floating (decimal

number)

%S

Format for text variable

%d

Format for integer

,

Separation character between output format

and parameter

;

End of block character

\n

Line break