Programming: Q parameters

9.7

Checking and changing Q parameters

9

300

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

9.7

Checking and changing Q parameters

Procedure

You can check Q parameters in all operating modes, and also edit

them.

If you are in a program run, interrupt it if required (for example,

by pressing the machine STOP button and the soft key). If you

are in a test run, interrupt it.

To call the Q parameter functions, press the

Q

INFO soft key or the Q key
The TNC lists all parameters and their current
values. Use the arrow keys or the

GOTO key to

select the desired parameter.
If you would like to change the value, press the

soft key, enter the new value, and confirm with the

ENT key.
To leave the value unchanged, press the soft key
or end the dialog with the

END key.

The parameters used by the TNC internally or in

cycles are provided with comments.
If you want to check or edit local, global or string
parameters, press the

SHOW PARAMETERS Q QL

QR QS soft key. The TNC then displays the specific

parameter type. The functions previously described

also apply.