Programming: Tools

5.2

Tool data

5

184

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

Tool usage test

The tool usage test function must be enabled by

your machine manufacturer. Refer to your machine

manual.

In order to be able to conduct a tool usage test, tool usage files

have to be generated, see page 536
The NC program has to be completely simulated in the

Test Run

operating mode or executed in the

Program Run, Full Sequence

or Single Block operating mode.

Applying the tool usage test

Before starting a program in the Program Run mode of operation,
you can use the

TOOL USAGE and TOOL USAGE TEST soft keys to

check whether the tools being used in the selected program are

available and have sufficient remaining service life. The TNC then

compares the actual service-life values in the tool table with the

nominal values from the tool usage file.
After you have pressed the

TOOL USAGE TEST soft key, the TNC

displays the result of the tool usage test in a pop-up window. To

close the pop-up window, press the ENT key.
The TNC saves the tool usage times in a separate file with the
extension

pgmname.I.T.DEP. This file is not visible unless the

machine parameter

CfgPgmMgt/dependentFiles is set to MANUAL.

The generated tool usage file contains the following information:

Column

Meaning

TOKEN

TOOL: Tool usage time per TOOL CALL.

The entries are listed in chronological

order.
TTOTAL: Total usage time of a tool
STOTAL: Call of a subprogram; the

entries are listed in chronological order
TIMETOTAL: The total machining time

of the NC program is entered in the

WTIME column. In the PATH column

the TNC saves the path name of the
corresponding NC programs. The

TIME

column shows the sum of all

TIME

entries (feed time without rapid traverse

movements). The TNC sets all other

columns to 0
TOOLFILE: In the PATH column, the

TNC saves the path name of the tool

table with which you conducted the test

run. This enables the TNC during the

actual tool usage test to detect whether

you performed the test run with the

TOOL.T

TNR

Tool number (

–1: No tool inserted yet)

IDX

Tool index

Advertising