background image

Dwell time FUNCTION FEED DWELL

11.6

11

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

387

Resetting dwell time

Reset to the dwell time immediately following the

machining with chip breaking.

Use

FUNCTION FEED DWELL RESET to reset the recurring dwell

time.
Proceed as follows for the definition:

Show the soft-key row with special functions

Select the menu for defining various plain-language

functions

Select the

FUNCTION FEED soft key

Select the

RESET FEED DWELL soft key

You can also reset the dwell time by entering D-TIME

0.
The TNC automatically resets the

FUNCTION FEED

DWELL function at the end of a program.

NC block

N40 FUNCTION FEED DWELL RESET*