Chapter 4: Sequence Commands

4-19

Shift it 3 bits towards the right.

Supplement

With the SFR command, when a number to be shifted >=

bit width, all data with a

designated bit width becomes 0.

SFR MB00100A N3 W5;

1 1 1 1 1 • • • • • •

• • • • • • • • •

9

5

0

MW00100

Before execution

0 0 0 1 1 • • • • • •

• • • • • • • • •

MW00100

“0” are input