MotionSuite™ Series Machine Controller Programming Manual

Chapter 2: Motion Commands

2-24

(2) When the switch set up for deceleration turns the accel/decel LS signal ON,

the feed speed decelerates to the value set up in the “Approach speed”
parameter.

• Servo amplifier user constant (Cn-0022): [Zero-point approach speed 1]

(3) After the switch departs from the deceleration LS, the speed is changed to the

value set up in the “Zero-point return traverse distance” parameter at the
previous C-phase position.

• Servo amplifier user constant (Cn-0023): [Zero-point approach speed 2]

(4) By creep speed, the position to which the axes move (from the position at

which the C-phase pulse is detected) only the distance set up by the “Zero-
point return traverse distance,” is set up as the machine coordinate zero-
point.

• Servo amplifier user constant (Cn-0028): [Zero-point return final traverse

distance]

b. Zero-point Return Motion 2

Execute the zero-point return motion which is shown as follows. The position to
which the axes return is the zero-point of the machine coordinate.

(1) Starts moving in the direction designated in the “Zero-point return direction”

parameter. The speed at this point is the value set in the parameter “Fast feed
speed”.

• Setup parameter 1 (OWxx00): [Motion mode b9: Zero-point return direc-

tion]

• Servo amplifier user constant (Cn-0023): [Zero-point approach speed 2]

v

t

(2)

Zero-point of
machine coordinate

Zero-point
LS signal

(1) Zero-point return feed speed

Final traverse distance

Figure 2.17: Motion Chart of the Zero-point Return Motion 2

Zero-point field