No-Load Operation Test Run

u

No-Load Operation Test Run

This section explains how to operate the drive with the motor uncoupled from the load during

a test run.

n

Before Starting the Motor

Check the following items before operation:
• Ensure the area around the motor is safe.
• Ensure external emergency stop circuitry is working properly and other safety precautions

have been taken.

n

During Operation

Check the following items during operation:
• The motor should rotate smoothly (i.e., no abnormal noise or oscillation).
• The motor should accelerate and decelerate smoothly.

n

No-Load Operation Instructions

The following example illustrates a test run procedure using the digital operator.

Note:

Before starting the motor, set the frequency reference d1-01 to 6 Hz.

Step

Display/Result

1. Turn on the power to the drive. The initial display appears.

2. Press the

key to select LOCAL. The LO/RE LED will turn

on.

STOP

4.7 No-Load Operation Test Run

114

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide