3 connecting peripheral devices, Connecting peripheral devices – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 182

Advertising
background image

7.3

Connecting Peripheral Devices

Figure 7.1

illustrates connections between the drive, motor, and various peripheral devices.

Refer to peripheral device option manual for detailed installation instructions.

Power
supply

Line
breaker
(MCCB)
or
Leakage
breaker

AC reactor

Input side
noise filter

DC link choke

Surge

suppressor

Option

Interface

unit

U/T1 V/T2 W/T3

R/L1 S/L2

+2

+1

T/L3

Ground

Output side
noise filter

Ground

Motor

B1 B2

DriveWizardPlus

Drive

Braking
resistor
unit

Copy

Verify

Read

LOCK

Y

ASKA

W

A

JVOP-181

USB Copy Unit

COM

ERR

PC

Engineering software tools

Dedicated Cable

(RJ-45/D-sub adapter)

(30cm)

RJ-45 cable
(1m)

USB Copy Unit

(RJ-45/USB adapter)

USB cable

<1>

<2>

Figure 7.1 Connecting Peripheral Devices

<1> NOTICE: Do not connect the LAN port on a PC and the comm. port of the RS-232/C

Interface Option Unit (SI-232/J and SI-232/JC). Failure to comply may damage the option

unit and the PC. Use the USB Copy Unit with an RJ-45 cable and USB cable as shown in

Figure 7.1

to connect the drive to a PC.

7.3 Connecting Peripheral Devices

182

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising