Yaskawa J1000 Compact V/f Control Drive User Manual
Page 249

n
EMC Filter Installation
The following conditions must be met to ensure continued compliance with guidelines.
Installation Method
Verify the following installation conditions to ensure that other devices and machinery used
in combination with this drive also comply with EMC guidelines.
1.
Install an EMC noise filter to the input side specified by Yaskawa for compliance with
European standards.
2.
Place the drive and EMC noise filter in the same enclosure.
3.
Use braided shield cable for the drive and motor wiring or run the wiring through a
metal conduit.
4.
Keep wiring as short as possible. Ground the shield on both the drive side and the
motor side.
5.
Ground the largest possible surface area of the shield to the metal conduit when using
braided shield cable. Yaskawa recommends using a cable clamp.
C.2 European Standards
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide
249
C
Standards Compliance