B.2 parameter table, A: initialization parameters – Yaskawa J1000 Compact V/f Control Drive User Manual
Page 215

B.2
Parameter Table
An “O” in the “Mode” column indicates that the parameter is available in the Advanced menu.
An “S” in the “Mode” column indicates that the parameter is available in the Startup menu.
u
A: Initialization Parameters
The A parameter group creates the operating environment for the drive. This includes the
parameter Access Level, and Password.
No.
Name
Description
Range Def. Mode Addr.
Hex
Pg.
A1: Initialization Parameters
Use A1 parameters to configure the basic environment for drive operation.
A1-01
<1>
Access Level
Selection
Selects which parameters are accessible via the
digital operator.
0: Operation only
2: Advanced Access Level
0, 2
2
O
101
A1-03 Initialize
Parameters
Resets all parameters to factory default settings.
(Initializes the drive then returns A1-03 to 0)
0: No Initialization
2220: 2-Wire Initialization
3330: 3-Wire Initialization
0 to
3330
0
O
103
E1-03, L8-35, o2-04, o2-09, and all U2
monitors are not reset when performing
initialization.
A1-04 Password
When the value set into A1-04 does not match the
value set into A1-05, parameters A1-01 and A1-03
cannot be changed.
0 to
9999
0
O
104
A1-05 Password
Setting
0 to
9999
0
O
105
This parameter is hidden from view. To
access A1-05, first display A1-04.
Then press the STOP key while holding
down the up arrow key. Parameter
A1-05 will appear.
<1>
Parameter can be changed during run.
B.2 Parameter Table
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide
215
B
Parameter List