No.

Name

Description

Range Def. Mode Addr.

Hex

Pg.

H3-13

Analog Input

Filter Time

Constant

Sets the primary delay filter time constant for

terminal A1 or potentiometer (optional). Used for

noise filtering.

0.00 to

2.00

0.03

s

O

41B

<1>

Parameter can be changed during run.

No.

Name

Description

Range Def. Mode Addr.

Hex

Pg.

H4: Multi-Function Analog Output AM

Use H4 parameters to configure the multi-function analog output terminal AM.

H4-01

Multi-

Function

Analog

Output

Terminal

AM

Selects the data to be output through multi-function

analog output terminal AM.

Set the desired monitor parameter to the digits

available in U-. For example, enter “103” for

U1-03.

When using this terminal in through mode or when

not using it at all, set “000” or “031”.

000 to

999

102

O

41D

105

H4-02

<1>

Multi-

Function

Analog

Output

Terminal AM

Gain

Sets terminal AM output level when selected

monitor is at 100%.

Maximum output voltage is 10 V.

-999.9

to 999.9

100.0

%

S

41E

105

H4-03

<1>

Multi-

Function

Analog

Output

Terminal AM

Bias

Sets terminal AM output level when selected

monitor is at 0%.

-999.9

to 999.9 0.0%

O

41F

105

H5: MEMOBUS/Modbus Communications

Use H5 Parameters to connect the drive to a MEMOBUS/Modbus network.

The settings for MEMOBUS/Modbus communications become effective when the drive is restarted.

H5-01

<2>

Drive Slave

Address

Selects drive slave number (address) for

MEMOBUS/Modbus communication. Cycle power

for the setting to take effect.

0 to FF

1F

O

425

H5-02 Comm. Speed

Selection

Selects the baud rate for MEMOBUS/Modbus

communication. Cycle power for the setting to take

effect.

0 : 1200 bps

1 : 2400 bps

2 : 4800 bps

3 : 9600 bps

4 : 19200 bps

5 : 38400 bps

0 to 5

3

O

426

H5-03 Comm. Parity

Selection

Selects the communication parity for MEMOBUS/

Modbus communication. Cycle power for the setting

to take effect.

0: No parity

1: Even parity

2: Odd parity

0 to 2

0

O

427