Refer to minor faults and, Minor faults and alarms, Operation errors – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 129: 3 drive alarms, faults, and errors

Advertising
background image

<2>

Displayed as

when occurring at drive power up. When one of the faults occurs after successfully

starting the drive, the display will show

.

<3>

Uv1 fault is not saved to the fault history

n

Minor Faults and Alarms

When a minor fault or alarm occurs, the ALM LED flashes and the text display shows an

alarm code. A fault has occurred if the text remains lit and does not flash.

Refer to Alarm

Detection on page 141

. An overvoltage situation, for example, can trigger both faults and

minor faults. It is therefore important to note whether the LEDs remain lit or if the LEDs flash.

Table 5.5 Minor Fault and Alarm Displays

Digital Operator

Display

Name

Minor Fault

Output

(H2- = 10)

Pg.

bb

Drive Baseblock

No output

141

CALL

Serial Communication Transmission Error

YES

141

CE

MEMOBUS/Modbus Communication Error

YES

141

CrST

Can Not Reset

YES

142

EF

Run Command Input Error

YES

142

to

EF1 to

EF5

External Fault (input terminal S1 to S5)

YES

143

oH

Heatsink Overheat

YES

143

oL3

Overtorque 1

YES

144

ov

Overvoltage

YES

144

PASS

MEMOBUS/Modbus Test Mode Complete

No output

145

SE

MEMOBUS/Modbus Test Mode Fault

YES

145

Uv

Undervoltage

YES

145

n

Operation Errors

Table 5.6 Operation Error Displays

Digital

Operator

Display

Name

Pg.

oPE01 Drive Unit Setting Error

147

oPE02 Parameter Setting Range

Error

147

oPE03 Multi-Function Input Setting

Error

147

Digital

Operator

Display

Name

Pg.

oPE05 Run Command Selection

Error

148

oPE10 V/f Data Setting Error

148

oPE11 Carrier Frequency Setting

Error

148

5.3 Drive Alarms, Faults, and Errors

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

129

5

Troubleshooting