Table 5.7 Detailed Fault Displays, Causes, and Possible Solutions

Digital Operator Display

Fault Name

CE

MEMOBUS/Modbus Communication Error
No data was received for longer than 2 seconds.

Cause

Possible Solution

Faulty communications wiring, or a

short circuit exists.

• Check for faulty wiring.
• Correct the wiring.
• Check for loose wiring and short circuits. Repair as needed.

A communications data error

occurred due to noise.

• Check the various options available to minimize the effects of noise.
• Counteract noise in control circuit, main circuit, and ground wiring.
• Use Yaskawa-recommended cables, or another type of shielded line. Ground

the shield on the controller side or on the drive input power side.

• Ensure that other equipment such as switches or relays do not cause noise and

use surge suppressors if required.

• Separate all wiring for communications devices from drive input power lines.

Install an EMC noise filter to the input side of the drive input power.

Digital Operator Display

Fault Name

CoF

Current Offset Fault
The current sensor is damaged or there was residual induction current in the motor

(e.g., during sudden deceleration or when coasting) when the drive attempted to

start the motor.

Cause

Possible Solution

Due to residual induction current in

the motor when the drive attempted

to start the motor, the drive

attempted to adjust the current

offset value beyond the allowable

range.

Create a motor restart sequence that allows enough time for the residual induction

voltage to dissipate.

Digital Operator Display

Fault Name

or

CPF00 or

CPF01

CPF11 – RAM Fault

CPF12 – Problem with the ROM (FLASH memory)

CPF14 – CPU error (CPU operates incorrectly due to noise, etc.)

CPF17 – A timing error occurred during an internal process

CPF18 – CPU error (CPU operates incorrectly due to noise, etc.)

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

5.4 Fault Detection

130

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising