Digital Operator Display

Minor Fault Name

Cause

Possible Solution

Minor Fault

(H2- =

10)

A data error occurred due to noise.

• Check options available to minimize the effects of noise.
• Counteract noise in the control circuit wiring, main circuit lines

and ground wiring.

• Reduce noise on the controller side.
• Use surge absorbers on magnetic contactors or other equipment

causing the disturbance.

• Use cables recommended by Yaskawa or another type of shielded

line. The shield should be grounded on the controller side or on

the drive input power side.

• Separate all wiring for communications devices from drive input

power lines. Install an EMC noise filter to the input side of the

drive input power.

YES

Communication protocol is

incompatible.

• Check the H5 parameter settings as well as the protocol setting in

the controller.

• Ensure settings are compatible.

The CE detection time (H5-09) is

set shorter than the time required for

a communication cycle to take

place.

• Check the PLC.
• Change the software settings in the PLC.
• Set a longer CE detection time (H5-09).

Incompatible PLC software

settings or there is a hardware

problem.

• Check the PLC.
• Remove the cause of the error on the controller side.

Communications cable is

disconnected or damaged.

• Check the connector for a signal through the cable.
• Replace the communications cable.

Digital Operator Display

Minor Fault Name

CrST

Can Not Reset

Cause

Possible Solution

Minor Fault

(H2- =

10)

Fault reset was being executed

when a Run command was entered.

• Ensure that a run command cannot be entered from the external

terminals or option card during fault reset.

• Turn off the Run command.

YES

Digital Operator Display

Minor Fault Name

EF

Forward/Reverse Run Command Input Error
Both forward run and reverse run closed simultaneously for longer than 0.5 s.

Cause

Possible Solution

Minor Fault

(H2- =

10)