Nuisance Tripping Resulting from High AC Drive Carrier Frequency

Current waveforms generated by high carrier frequency PWM drives tend to create additional

temperature rise in overload relays. Therefore, it may be necessary to increase the trip level

setting when encountering nuisance triggering of the relay.

WARNING! Fire Hazard. Confirm an actual motor overload condition is not present prior to increasing the

thermal oL trip setting. Check local electrical codes before making adjustments to motor thermal overload

settings.

u

NEMA Type 1 Kit

WARNING! Fire Hazard. Provide sufficient cooling when installing the drive inside an enclosed panel or

cabinet. Failure to comply could result in overheating and fire. When multiple drives are placed inside the

same enclosure panel, install proper cooling to ensure air entering the enclosure does not exceed 40 °C.

The optional NEMA Type 1 kit can be installed to raise the enclosure protection level of an

IP20/Open-Chassis drive to NEMA Type 1. Drives with a NEMA Type 1 kit cannot be

installed using side-by-side mounting unless the top cover is removed. The drive does not

retain NEMA Type 1 integrity with the top cover removed.

Refer to Installation Orientation

and Spacing on page 30

for installation instructions.

n

Installation Environment

Table 7.2 Installation Environment

Environment

Conditions

Ambient

Temperature

-10 °C to +40 °C (NEMA Type 1/wall-mounted enclosure)

Drive reliability improves in environments without wide temperature fluctuations.

When using an enclosure panel, install a cooling fan or air conditioner in the area to ensure

that the air temperature inside the enclosure does not exceed the specified levels.

Do not allow ice to develop on the drive.

Refer to Installation Environment on page 29

for all other installation environment specifications.

7.4 Installing Peripheral Devices

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide