<2>

This alarm message will always be output, even if the Maintenance Monitor function is not assigned to any of
the digital outputs (H2- = 2F). The alarm will also trigger a digital output that is programmed for alarm
indication (H2- = 10).

n

Related Drive Parameters

Use parameters o4-03, o4-05, o4-07, and o4-09 to reset a Maintenance Monitor to zero after

replacing a specific component.

Refer to Parameter List on page 213

for details on parameter

settings.

NOTICE: If these parameters are not reset after the corresponding parts have been replaced, the

Maintenance Monitor function will continue to count down the performance life from the value that was reached

with the old part. If the Maintenance Monitor is not reset, the drive will not have the correct value of the

performance life for the new component.

6.3 Periodic Maintenance

170

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide