B.3 defaults by drive model and duty rating nd/hd, B.3 defaults by drive model and duty, Rating nd/hd – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 238

Advertising
background image

B.3

Defaults by Drive Model and Duty Rating
ND/HD

Table B.2 Single-Phase, 200 V Class Drives Default Settings by Drive Capacity and ND/HD Settings

No.

Description

Unit

Default Settings

Model

BA0001

BA0002

BA0003

o2-04

Drive Model Selection

Hex

30

31

32

C6-01

Normal/Heavy Duty

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

Motor rated power

kW

0.1

0.18

0.25

0.37

0.55

0.75

C6-02

Carrier frequency

4

7

4

7

4

7

E2-01

Motor rated current

A

0.60

1.10

1.10

1.90

1.90

3.30

E2-02

Motor rated slip

Hz

2.50

2.60

2.60

2.90

2.90

2.50

E2-03

Motor no-load current

A

0.40

0.80

0.80

1.20

1.20

1.80

E2-05

Motor line-to-line resistance

Ω

35.98

20.56

20.56

9.84

9.842

5.156

Momentary power loss ride-

through time

s

0.1

0.1

0.1

0.1

0.1

0.1

Mom. power loss Baseblock

time

s

0.2

0.2

0.2

0.2

0.2

0.3

No.

Description

Unit

Default Settings

Model

BA0006

BA0010

o2-04

Drive Model Selection

Hex

33

34

C6-01

Normal/Heavy Duty

HD

ND

HD

ND

0

1

0

1

C6-02

Carrier frequency

4

7

3

7

E2-01

Motor rated current

A

3.30

6.20

6.20

8.50

E2-02

Motor rated slip

Hz

2.50

2.60

2.60

2.90

E2-03

Motor no-load current

A

1.80

2.80

2.80

3.00

E2-05

Motor line-to-line resistance

Ω

5.156

1.997

1.997

1.601

Momentary power loss ride-through time

s

0.2

0.2

0.3

0.3

Momentary power loss Baseblock time

s

0.3

0.4

0.4

0.5

B.3 Defaults by Drive Model and Duty Rating ND/HD