B.3 defaults by drive model and duty rating nd/hd – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 240

Advertising
background image

Table B.4 Three-Phase 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting

No.

Description

Unit

Default Settings

Model

4A0001

4A0002

4A0004

4A0005

o2-04

Drive Model Selection Hex

91

92

93

94

C6-01

Normal/Heavy Duty

HD

ND

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

0

1

Motor rated power

kW

0.37

0.37

0.55

0.75

1.1

1.5

1.5

2.2

C6-02

Carrier frequency

3

7

3

7

3

7

3

7

E2-01

Motor rated current

A

0.60

1.00

1.00

1.60

1.60

3.10

3.10

4.20

E2-02

Motor rated slip

Hz

2.50

2.90

2.90

2.60

2.60

2.50

2.50

3.00

E2-03

Motor no-load current

A

0.40

0.60

0.60

0.80

0.80

1.40

1.40

1.50

E2-05

Motor line-to-line

resistance

Ω

83.94

38.20 38.198 22.459 22.459

10.1

10.1

6.495

Momentary power loss

ride-through time

s

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

Momentary power loss

Baseblock time

s

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.5

No.

Description

Unit

Default Setting

Model

4A0007

4A0009

4A0011

o2-04

Drive Model Selection

95

96

97

C6-01

Normal/Heavy Duty

HD

ND

HD

ND

HD

ND

0

1

0

1

0

1

Motor rated power

kW

2.2

3.0

3.0

4.0

4.0

5.5

C6-02

Carrier frequency

3

7

3

7

3

7

E2-01

Motor rated current

A

4.20

5.70

5.70

7.00

7.00

9.80

E2-02

Motor rated slip

Hz

3.00

2.70

2.70

2.70

2.70

1.50

E2-03

Motor no-load current

A

1.50

1.90

1.90

2.30

2.30

2.60

E2-05

Motor line-to-line resistance

Ω

6.495

4.360

4.360

3.333

3.333

1.595

Momentary power loss ride-

through time

s

0.5

0.5

0.5

0.5

0.5

0.5

Momentary power loss

Baseblock time

s

0.5

0.5

0.5

0.6

0.6

0.7

B.3 Defaults by Drive Model and Duty Rating ND/HD

240

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising