B.2 parameter table – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 237

Advertising
background image

No.

Name

Description

Analog Output

Level

Unit Mode Addr.

Hex

U2: Fault History

Use U2 monitors to view fault history data.

U2-01 Current Fault Displays the current fault.

No signal output

avail.

O

80

U2-02 Previous

Fault

Displays the previous fault. o4-11 resets the

values for U2-02

No signal output

avail.

O

81

U4: Maintenance Monitors

Use U4 monitors to display drive maintenance information.

U4-01

<3>

Accumulated

Operation

Time

Displays the cumulative operation time of the

drive. The value for the cumulative operation

time counter can be reset in parameter o4-01.

Use parameter o4-02 to determine if the

operation time should start as soon as the power

is switched on or only while the run command

is present. The maximum number displayed is

99999, after which the value is reset to 0.

No signal output

avail.

1 h

O

4C

U4-04 Cooling Fan

Maintenance

Displays main cooling fan usage time as a

percentage of the expected performance life.

Parameter o4-03 can be used to reset this

monitor.

No signal output

avail.

1%

O

7E

U4-05

<2>

Capacitor

Maintenance

Displays main circuit capacitor usage time as a

percentage of the expected performance life.

Parameter o4-05 can be used to reset this

monitor.

No signal output

avail.

1%

O

7C

U4-06

<2>

Soft Charge

Bypass Relay

Maintenance

Displays the soft charge bypass relay

maintenance time as a percentage of the

estimated product life. Parameter o4-07 can be

used to reset this monitor.

No signal output

avail.

1%

O

7D6

U4-07

<2>

IGBT

Maintenance

Displays IGBT usage time as a percentage of

expected performance life. Parameter o4-09 can

be used to reset this monitor.

No signal output

avail.

1%

O

7D7

U4-08 Heatsink

Temperature

Displays the heatsink temperature.

10 V: 100 °C

1 °C

O

68

U4-09 LED Check

Lights all segments of the LED to verify that the

display is working properly.

No signal output

avail.

O

3C

U4-13 Peak Hold

Current

Displays the peak hold current during run.

No signal output

avail.

0.01

A

<1>

O

7CF

<1>

U1-03 and U4-13 display monitor contents in amp units. When reading the value of these monitors via
MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.

<2>

When this value reaches 100%, the maintenance period has been reached for the component in question and the
drive is at risk of faulting out due to component failure. Periodically check the maintenance monitors to avoid
this situation.

<3>

MEMOBUS/Modbus communications data is in 10 h units. If data in 1 h units are also required, refer to register
0099H.

B.2 Parameter Table

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

237

B

Parameter List