4.9

Verifying and Backing Up Parameter
Settings

Check changes to parameter settings using the Verify function.

Refer to Verifying Parameter

Changes: Verify Menu on page 84

.

Save the verified parameter settings. Change the access level or set a password to the drive to

prevent accidental modification of parameter settings.

u

Parameter Access Level: A1-01

Setting the Access Level for “Operation only” (A1-01 = 0) allows the user to access parameters

A1- and U- only. Other parameters are not displayed.

No.

Parameter

Name

Description

Setting

Range

Default

A1-01 Access Level

Selection

Selects which parameters are accessible via the digital operator.

0: Operation only (A1-01 and A1-04 can be set and monitored. U

parameters can be monitored)

2: Advanced Access Level (All parameters can be set and monitored)

0, 2

2

u

Password Settings: A1-04, A1-05

The user can set a password to the drive to restrict access. The password is selected via

parameter A1-05. The selected password must be entered in parameter A1-04 to unlock

parameter access (i.e., parameter setting A1-04 must match the value programmed into

A1-05). The following parameters cannot be viewed or edited until the value programmed

into A1-04 correctly matches the value as programmed in parameter A1-05: A1-01 and A1-03.

Note:

Parameter A1-05 is hidden from view. To display A1-05, access parameter A1-04 and simultaneously

depress the

key and the

key.

u

Copy Function (Optional)

Parameter settings can be copied to another drive to simplify parameter restoration or multiple

drive setup. The RS-232C Interface Unit (Removable Type) (SI-232/JC) is required to use

the following options with J1000 drives:

n

USB/Copy Unit (JVOP-181)

The copy unit is an external option connected to the drive to copy parameter settings to another

drive. It includes a USB adapter to connect the drive to a PC.

4.9 Verifying and Backing Up Parameter Settings

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

117

4

Start-Up Programming & Operation

Advertising