Poor speed control accuracy – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 155

Advertising
background image

n

Motor Will Not Accelerate or the Acceleration Time is Too Long

Cause

Possible Solutions

Frequency reference is too low.

• Check the maximum output frequency (E1-04).
• Increase E1-04 if it is set too low.
Check U1-01 for proper frequency reference.
Check if a frequency reference signal switch has been set to one of the multi-

function input terminals.
Check for low gain level set to terminal A1 (H3-03).

Load is too heavy.

• Reduce the load so that the output current remains within the motor-rated

current.

• In extruder and mixer applications, the load will sometimes increase as

the temperature drops.

Check if the mechanical brake is fully releasing as it should.

Acceleration time has been set too long. Check if the acceleration time parameters have been set too long (C1-01,

-03).

Motor characteristics and drive parameter

settings are incompatible with one

another in V/f Control.

• Set the correct V/f pattern so that it matches the characteristics of the

motor being used.

• Check the motor data and adjust V/f pattern settings.

Incorrect frequency reference setting.

• Check the multi-function analog input settings.
• Ensure the analog input value is set to the right value (U1-13).

The Stall Prevention level during

acceleration and deceleration set too low.

• Check the Stall Prevention level during acceleration (L3-02).
• If L3-02 is set too low, acceleration will take a fair amount of time.
• Increase L3-02.

The Stall Prevention level during run has

been set too low.

• Check the Stall Prevention level during run (L3-06).
• If L3-06 is set too low, speed will drop as the drive outputs torque.
• Increase the setting value.

n

Drive Frequency Reference Differs from the Controller Frequency

Reference Command

Cause

Possible Solutions

The analog input frequency gain and bias

are set to incorrect values.

Check the frequency reference terminal input gain level assigned to terminal

A1 (parameter H3-03).

n

Poor Speed Control Accuracy

Cause

Possible Solutions

Slip compensation function disabled or

set up incorrectly.

Adjust the slip compensation gain (C3-01).

5.8 Troubleshooting without Fault Display

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

155

5

Troubleshooting

Advertising