Drive mode details – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 81

Advertising
background image

Drive Mode

Output Voltage Reference

STOP

Monitors the output voltage of the drive.

Monitor Display

STOP

Monitor parameters (U parameters) are displayed.

Programming

Mode

Verify Function

STOP

Lists all parameters that have been edited or changed from default

settings.

Refer to Verifying Parameter Changes: Verify Menu

on page 84

.

Setup

STOP

A select list of parameters necessary to get the drive operational

quickly.

Refer to The Setup Group within the Programming

Mode on page 82

.

Parameter Setting

STOP

Allows the user to access and edit all parameter settings.

Refer to

Parameter List on page 213

.

Drive Mode

Frequency Reference

STOP

Returns to the frequency reference display screen.

n

Drive Mode Details

The following actions are possible in the Drive Mode:
• Run and stop the drive.
• Monitor the operation status of the drive (frequency reference, output frequency, output

current, output voltage, etc.).

• View information on an alarm.

Note:

Select "Drive Mode" when running. The mode can be switched to any mode (program mode, etc.) other

than drive mode while the drive is stopped. However, the drive cannot be operated in other modes. Return

the mode to "Drive Mode" after completing periodic inspection.

Figure 4.4

illustrates changing the default frequency reference of F 0.00 (0 Hz) to F 6.00 (6

Hz) while in Drive Mode. This example assumes the drive is set to LOCAL.

4.3 The Drive and Programming Modes

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

81

4

Start-Up Programming & Operation