5 basic operation – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 94

Advertising
background image

n

Switching Accel/Decel Times with Digital Input Terminals

Two acceleration / deceleration times can be selected using one of the digital input terminals

S1 through S5.
Program one of the parameters H1-01 through H1-05 to “07” (Accel/Decel Time). Opening

or closing the digital input changes the accel/decel times as shown below:

Accel/Decel Time

H1- = 7

Acceleration Time

Deceleration Time

Open (not selected)

C1-01

C1-02

Closed

C1-03

C1-04

n

Using S-Curve Characteristics during Acceleration/Deceleration

Use S-curve characteristics to smooth acceleration and deceleration and to minimize abrupt

shock to the load.

Note:

Setting S-curve characteristics will lengthen accel/decel times as follows:

Accel Time = Selected Accel Time + (C2-01 + C2-02)/2

Decel Time = Selected Decel Time + (C2-03 + C2-04)/2

Setting Example

Figure 4.13

illustrates S-curve characteristics switching between forward and reverse.

C2-02

C2-01

C2-03

C2-04

C2-02

C2-01

C2-03

C2-04

Forward Run

Command
Reverse Run

Command

Output

Frequency

Figure 4.13 S-Curve Characteristics

4.5 Basic Operation

94

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising