Three-Phase 400 V Class Drives

Table A.3 Power Ratings

Item

Specification

Three-Phase Drive Model

4A0001

4A0002

4A0004 4A0005 4A0007 4A0009 4A0011

Maximum Applicable Motor

Capacity (HP)

<1>

ND Rating

0.5

0.75 &

1

2

3

4

5

7.5

HD Rating

0.5

0.75

1 & 2

3

3

3

5

Input

Input Current (A)

<2>

ND Rating

1.2

2.1

4.3

5.9

8.1

9.4

14.0

HD Rating

1.2

1.8

3.2

4.4

6.0

8.2

10.4

Output

Output Current

(kVA)

<3>

ND Rating

<4>

0.9

1.6

3.1

4.1

5.3

6.7

8.5

HD Rating

<5>

0.9

1.4

2.6

3.7

4.2

5.5

7.0

Output Current (A)

ND Rating

<4>

1.2

2.1

4.1

5.4

6.9

8.8

11.1

HD Rating

<5>

1.2

1.8

3.4

4.8

5.5

7.2

9.2

Overload Tolerance

ND Rating: 120% of rated output current for 60 s

HD Rating: 150% of rated output current for 60 s

(Derating may be required for applications that start and stop

frequently)

Carrier Frequency

2 kHz (user-adjustable from 2 to 15 kHz)

Maximum Output Voltage (V)

Three-phase power: 380 to 480 V (proportional to input voltage)

Maximum Output Frequency (Hz)

400 Hz (user-adjustable)

Power

Supply

Rated Voltage

Rated Frequency

Three-phase power: 380 to 480 V 50/60 Hz

DC power supply: 510 to 680 V

<6>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Harmonic Corrective Actions

DC Link

Choke

Optional

<1>

Horsepower rating is based on 460 V Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in
NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.

<2>

Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and
power supply impedance.

<3>

Rated motor capacity is calculated with a rated output voltage of 440 V.

<4>

Carrier frequency is set to 2 kHz (Swing PWM). Current derating is required to raise the carrier frequency.

<5>

Carrier frequency is set to 8 kHz. Current derating is required to raise the carrier frequency.