2 drive options and peripheral devices, Drive options and peripheral devices180 – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 180

Advertising
background image

7.2

Drive Options and Peripheral Devices

The following table of peripheral devices lists the names of the various devices/options

available for Yaskawa drives. Contact Yaskawa or your Yaskawa agent to order these

peripheral devices.
Peripheral Device Selection: Refer to Yaskawa catalog for selection and part numbers.
Peripheral Device Installation: Refer to option manual for option installation instructions.

Table 7.1 Available Peripheral Devices

Option

Model Number

Description

Power Options

DC Link Choke

UZDA Series

DC link choke to improve power factor

AC Reactor

UZBA Series

AC reactor to improve power factor

Braking Resistor

<1>

ERF-150WJ Series

3% ED, 150 W braking resistor

Surge Absorber

200 V class: DCR2-

A

400 V class:

RFN3AL-504KD

Suppresses surge voltage caused by switching magnetic

contactors

Molded Case Circuit

Breaker

NF Series

Circuit breaker for short circuit or overload protection

Note: Yaskawa recommends installing an MCCB to the power

supply side to protect drive wiring and to prevent other damage in

the event of component failure. Install an MCCB if permitted by

the power system.

Ground Fault Circuit

Interrupter (GFCI)

NV, EG, or SG Series

Provides protection against potentially harmful leakage currents

Note: Yaskawa recommends installing a GFCI to the power

supply side to protect drive wiring and to prevent other damage in

the event of component failure. An MCCB can also be used if

permitted by the power system.

Magnetic Contactor

(Input)

SC Series

Prevents potential damage to the braking resistor and other internal

circuitry by ensuring that power to drive is completely shut off

when necessary. Install an MCCB when using a braking resistor

to prevent the braking resistor from overheating.

Wire the MC so that it opens when a fault output terminal is

triggered to protect internal components from sudden high levels

of input current.

Interface Options

Remote LED Operator

JVOP-182

Remote operator with LED display and copy function; Cable

length max. 3 m

USB/Copy Unit

JVOP-181

Allows the user to copy and verify parameter settings between

drives. Can also be used as adapter to connect the drive to a PC

USB port.

Note: SI-232/JC option is required

RS-232C Serial

Communication Interface SI-232/JC

RS-232/C communications interface to either connect the drive to

a PC, to the optional copy unit, or to the external LED operator

JVOP-182.

7.2 Drive Options and Peripheral Devices

180

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

Advertising