A.2 single/three-phase 200 v class drives – Yaskawa J1000 Compact V/f Control Drive User Manual
Page 202

<4>
Rated motor capacity is calculated with a rated output voltage of 220 V.
<5>
Carrier frequency is set to 2 kHz (Swing PWM). Current derating is required to raise the carrier frequency.
<6>
Carrier frequency is set to 10 kHz. Current derating is required to raise the carrier frequency.
<7>
Carrier frequency is set to 8 kHz. Current derating is required to raise the carrier frequency.
<8>
DC is not available for UL standards.
Note:
Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated
input and output current, overload capacity, carrier frequency and current limit. Set parameter C6-01 to
“0” for HD or “1” for ND (default).
A.2 Single/Three-Phase 200 V Class Drives
202
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide