Step

Display/Result

3.

Press

to enter the list of parameters that have been edited

from their original default settings.

Scroll through the list by pressing the

key.

4.

Press the

key until C1-01 appears.

5. Press the

key to access the setting value. (number farthest

to the left flashes)

u

Switching Between LOCAL and REMOTE

Entering the run command using the LED operator is referred to as LOCAL, while entering

the run command from an external device via the control circuit terminals or network option

is referred to as REMOTE.

WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already

applied when switching from LOCAL mode to REMOTE mode when b1-07 = 1, resulting in death or serious

injury. Be sure all personnel are clear of rotating machinery and electrical connections prior to switching

between LOCAL mode and REMOTE mode.

There are two ways to switch between LOCAL and REMOTE.

Note:

1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.

n

Using the LO/RE Key on the LED Operator

Step

Display/Result

1. Turn on the power to the drive. The initial display appears.

2.

Press

. The LO/RE light will light up. The drive is now in

Local.

To set the drive for REMOTE operation, press the

key again.

STOP

4.3 The Drive and Programming Modes

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

85

4

Start-Up Programming & Operation