A.4 drive specifications – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 205

Advertising
background image

A.4

Drive Specifications

Note:

For optimum performance life of the drive, install the drive in an environment that meets the

environmental conditions.

Item

Specification

Control

Characteristics

Control Method

V/f Control

Frequency Control

Range

0.01 to 400 Hz

Frequency Accuracy

Digital input: within ±0.01% of the max output frequency (-10 to +50

°C)

Analog input: within ±0.5% of the max output frequency (25 °C ±10 °C)

Frequency Setting

Resolution

Digital inputs: 0.01 Hz

Analog inputs: 1/1000 of maximum output frequency

Output Frequency

Calculation

Resolution

1/2

20

x Maximum output frequency (E1–04)

Frequency Setting

Signal

Main frequency reference: 0 to +10 Vdc (20 kΩ), 4 to 20 mA (250 Ω),

0 to 20 mA (250 Ω)

Starting Torque

150%/3 Hz

Speed Control Range 1: 20~40

Accel/Decel Time

0.00 to 6000.0 s (allows four separate settings for accel and decel)

Braking Torque

Instantaneous Average Decel Torque

<1>

: 0.1/0.2 kW: over 150%,

0.4/0.75 kW: over 100%, 1.5 kW: over 50%, 2.2 kW and above: over

20%

Continuous Regen Torque: 20%,
125% with a Braking Resistor Unit

<2>

: (10% ED) 10 s with an internal

braking resistor.

V/f Characteristics

User-set, programmable.

Functions

• Momentary Power Loss Ride-Thru
• Speed Search
• Multi-Step Speed (9 steps max)
• Accel/Decel Time Switch
• S-Curve Accel/Decel
• 2-Wire/3-Wire Sequence
• Cooling Fan ON/OFF
• Slip Compensation
• Torque Compensation
• Jump Frequencies (reference dead band)
• Frequency Reference Upper/Lower Limit
• DC Injection Braking (start and stop)
• Overexcitation Braking
• Fault Reset

A.4 Drive Specifications