A.1 heavy duty and normal duty ratings, A.1 heavy duty and normal duty ratings 200 – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 200

Advertising
background image

A.1

Heavy Duty and Normal Duty Ratings

The capacity of the drive is based on two types of load characteristics: Heavy Duty (HD) and

Normal Duty (ND).

Refer to Selecting the Appropriate Load Rating on page 200

for the differences between

HD and ND. Specifications for capacity ratings are listed on the following pages.

Table A.1 Selecting the Appropriate Load Rating

Setting

Parameter

C6-01

Rated Output Current

Overload Tolerance

Default Carrier

Frequency

0: Heavy Duty

HD Rating
varies by model

<1>

150% rated output current for 60 s

8/10 kHz

varies by model

1: Normal Duty

(default)

ND Rating
varies by model

<1>

120% rated output current for 60 s

varies by model

2 kHz, Swing PWM

<1>

The following pages list information on rating changes based on drive model.

TERMS

TERMS

HD and ND: HD refers to applications requiring constant torque output,

while ND refers to applications with variable torque needs. The drive allows

the user to select HD or ND torque depending on the application. Fans,

pumps, and blowers should use ND (C6-01 = 1), and other applications

generally use HD (C6-01 = 0).

Swing PWM: Swing PWM equivalent to a 2 kHz audible noise. This

function turns the motor noise into a less obtrusive white noise.

Note:

Differences between HD ratings and ND ratings for the drive include rated input and output current,

overload capacity, carrier frequency, and current limit. The default setting is for ND (C6-01 = 1).

A.1 Heavy Duty and Normal Duty Ratings

200

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide