9 main frequency reference – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 63

Advertising
background image

Table 3.12 DIP Switch S1 Settings

Setting Value

Description

V ( right position)

Voltage input (0 to 10 V): default setting

I ( left position)

Current input (4 to 20 mA or 0 to 20 mA)

Table 3.13 Parameter H3-01 Details

No.

Parameter Name

Description

Setting

Range

Default

Setting

MEMOBUS

Register

H3-01

Frequency ref.

(voltage/current)

terminal A1 signal

level selection

Selects the signal level for terminal A1.

0: 0 to +10 V, unipolar input (negative

frequency reference values are zeroed)

1: 0 to +10 V, bipolar input (negative

frequency reference changes the direction)

2: 4 to 20 mA

3: 0 to 20 mA

0 to 3

0

410

3.9 Main Frequency Reference

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

63

3

Electrical Installation

Advertising