4.5 Test Without Motor Function

4-31

4

Ope

rat

ion

4.5.3 Limitations

The following functions cannot be used during the test without a motor.

• Regeneration and dynamic brake operation
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the Sig-

maWin+.)

• Items marked with "

×" in the following utility function table.

Note:

: Can be used

× : Cannot be used

Fn No.

Contents

Can be

used or not

Motor not

connected

Motor con-

nected

Fn000

Alarm history display

Fn002

JOG operation

Fn003

Origin search

Fn004

Program JOG operation

Fn005

Initializing parameter settings

Fn006

Clearing alarm history

Fn008

Absolute encoder multiturn reset and encoder alarm reset

×

Fn00C

Offset adjustment of analog monitor output

Fn00D

Gain adjustment of analog monitor output

Fn00E

Automatic offset-signal adjustment of the motor current detection signal

×

Fn00F

Manual offset-signal adjustment of the motor current detection signal

×

Fn010

Write prohibited setting

Fn011

Servomotor model display

Fn012

Software version display

Fn013

Multiturn limit value setting change when a multiturn limit disagreement alarm
occurs

×

Fn014

Resetting configuration error in option modules

Fn01B

Vibration detection level initialization

×

×

Fn01E

Display of SERVOPACK and servomotor ID

Fn01F

Display of servomotor ID in feedback option module

Fn020

Origin setting

×

Fn030

Software reset

Fn200

Tuning-less levels setting

×

×

Fn201

Advanced autotuning

×

×

Fn202

Advanced autotuning by reference

×

×

Fn203

One-parameter tuning

×

×

Fn204

Anti-resonance control adjustment function

×

×

Fn205

Vibration suppression function

×

×

Fn206

EasyFFT

×

×

Fn207

Online vibration monitor

×

×

Advertising