6 Utility Functions (Fn

)

6-32

6.19 Origin Setting (Fn020)

When using an external absolute encoder for fully-closed loop control, this function is used to set the current

position of the external absolute encoder as the origin (zero point position).

This function can be used with the following products.

Mitutoyo Corporation

ABS ST780A series
Model: ABS ST78 A/ST78 AL

(1) Preparation

The following conditions must be met to set the origin.

• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be OFF.

(2) Operating Procedure

Use the following procedure.

• After execution of origin setting, the servo ready (/S-RDY) signal will become inactive

because the system position data will have been changed. Always turn the power
supply OFF and then ON again after execution of origin setting.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main menu for the

utility function.
Use the

or

Key to move through the list and

select Fn020.

2

Press the

Key. The display changes to the Fn020

execution display.

3

Press the

or

Key to "ORGSET5".

4

Press the

key to start setting the origin. The mes-

sage, "Scale Origin Set," flashes while the origin is
being set. After the origin has been successfully set,
the displayed status changes as follows: "BB" to
"DONE" to "BB".

5

To enable the change in the setting, turn the power OFF and ON again.

B B

− F U N C T I O N −

F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S

− O r i g S e t

F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t

46 and
64

B B

S c a l e O r i g i n S e t

O R G S E T 1

B B

S c a l e O r i g i n S e t

O R G S E T 5

B B

S c a l e O r i g i n S e t