5.3 Advanced Autotuning (Fn201)

5-25

5

Adjustm

e

nts

Friction Compensation

This function compensates for changes in the following conditions.

• Changes in the viscous resistance of the lubricant, such as the grease, on the sliding parts of the machine
• Changes in the friction resistance resulting from variations in the machine assembly
• Changes in the friction resistance due to aging

The conditions for applying friction compensation depend on the mode. The friction compensation setting in

Pn408.3 applies when the Mode is 1. The friction compensation function is always enabled regardless of the

friction compensation setting in Pn408.3 when the Mode is 2 or 3.

Feedforward

If Pn140 is set to the factory setting and the mode setting is changed to 2 or 3, the feedforward gain (Pn109),

speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled.

Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and
torque feedforward (TFF) input from the host controller.

Refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54) for details.

Mode = 1

Mode = 2

Mode = 3

Pn408

n.0
[Factory
setting]

Adjusted without the friction
compensation function

Adjusted with the friction

compensation function

Adjusted with the friction

compensation function

n.1

Adjusted with the friction

compensation function

Mode

Friction

Compensation

Selecting

Parameter

Function

When Enabled Classification

Pn140

n.0
[Factory setting]

Model following control is not used together with the
speed/torque feedforward input.

Immediately

Tuning

n.1

Model following control is used together with the
speed/torque feedforward input.

• Model following control is used to make optimum feedforward settings in the SERVO-

PACK when model following control is used with the feedforward function. Therefore,
model following control is not normally used together with either the speed feedfor-
ward (VFF) input or torque feedforward (TFF) input from the host controller. However,
model following control can be used with the speed feedforward (VFF) input or torque
feedforward (TFF) input if required. An improper feedforward input may result in over-
shooting.