10.1 List of Parameters

10-31

10

Ap

pend

ix

Pn833

2

Motion Setting

0000 to 0001

0000

After restart

Setup

*1

Pn834

4

1st Linear Acceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*5

Setup

*1

Pn836

4

2nd Linear Acceleration
Constant 2

1

to

20971520

10000

reference

unit/s

100

Immediately

*5

Setup

*1

Pn838

4

Acceleration Constant
Switching Speed 2

0 to

2097152000

1

reference

unit/s

0

Immediately

*5

Setup

*1

Pn83A

4

1st Linear Deceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*5

Setup

*1

Pn83C

4

2nd Linear Deceleration
Constant 2

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*5

Setup

*1

Pn83E

4

Deceleration Constant
Switching Speed 2

0

to

2097152000

1

reference

unit/s

0

Immediately

*5

Setup

*1

Pn840

4

Linear Deceleration
Constant 2 for Stopping

1

to

20971520

10000

reference

unit/s

2

100

Immediately

*5

Setup

*1

Pn842

*7

4

Homing Approach Speed 12

0 to

20971520

100

reference

unit/s

0

Immediately

*5

Setup

*1

Pn844

*8

4

Homing Approach Speed 22

0 to

20971520

100

reference

unit/s

0

Immediately

*5

Setup

*1

Pn850

2

Latch Sequence Number

0

to

8

0

Immediately

Setup

*1

Pn851

2

Continuous Latch Count

0

to

255

0

Immediately

Setup

*1

∗1. For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).

∗5. Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during

operation.

∗7. The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use

Pn842.

∗8. The set value of Pn844 is valid when the set value of Pn818 is 0. Software version 0023 or higher is required to use

Pn844.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Linear Accel/Decel Constant Selection

0

1

Uses Pn80A to Pn80F and Pn827. (Setting of Pn834 to Pn840 disabled)

Uses Pn834 to Pn840. (Setting of Pn80A to Pn80F and Pn827 disabled)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Advertising