5 absolute data reception sequence, 1) outline of absolute data, 2) absolute data reception sequence – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 128: 46 and 64, Phase-c output specifications

Advertising
background image

4.7 Absolute Encoders

4-43

4

Ope

rat

ion

4.7.5 Absolute Data Reception Sequence

The sequence in which the SERVOPACK receives outputs from the absolute encoder and transmits them to

host controller is shown below.

(1) Outline of Absolute Data

The serial data, pulses, etc., of the absolute encoder that are output from the SERVOPACK are output from the
PAO, PBO, and PCO signals as shown below.

Phase-C Output Specifications

The pulse width of phase C (origin pulse) changes depending on the encoder output pulse (Pn212), becoming

the same width as phase A.

The output timing is one of the following.

• Synchronized with the rising edge of phase A
• Synchronized with the falling edge of phase A
• Synchronized with the rising edge of phase B
• Synchronized with the falling edge of phase B

Note: When host controller receives the data of absolute encoder, do not perform counter reset using the output of PCO

signal.

(2) Absolute Data Reception Sequence

1. Send the Turn Encoder Power Supply ON (SENS_ON) command from the host controller.
2. After 100 ms, the system is set to rotational serial data reception standby and the incremental pulse up/

down counter is cleared to zero.

3. Eight characters of rotational serial data is received.
4. The system enters a normal incremental operation state about 400 ms after the last rotational serial data is

received.

Note: The output pulses are phase-B advanced if the servomotor is turning forward regardless of the setting in Pn000.0.

Signal Name

Status

Contents

PAO

At initialization

Rotational serial data
Initial incremental pulses

Normal Operations

Incremental pulses

PBO

At initialization

Initial incremental pulses

Normal Operations

Incremental pulses

PCO

Always

Origin pulses

ENC

CN1

PAO

PBO

PCO

CN2

Serial

data

Serial data→
pulse conversion

Host
controller

SERVOPACK

Dividing

circuit

(Pn212)

46 and 64

PAO

PBO

SENS_ON
(Turn Encoder
Power Supply ON)

Incremental pulses

Incremental pulses

Undefined

Undefined

(Phase A) (Phase A)

(Phase B) (Phase B)

Rotational
serial data

400 ms max.

50 ms

1 to 3 ms

Approx. 15 ms

90 ms typ.

60 ms min.

Initial
incremental
pulses

Initial
incremental
pulses

46

Advertising