Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 363

Advertising
background image

10.1 List of Parameters

10-33

10

Ap

pend

ix

Pn882

2

Transmission Cycle Setting
Monitor [0.25

μs]

(for maintenance, read only)

0 to FFFFH

0

Immediately

Setup

Pn883

2

Communications Cycle Setting
Monitor

[x transmission cycle]
(for maintenance, read only)

0 to 32

0

Immediately

Setup

Pn884

2

Communications Controls 2

0000 to 0001

0000

Immediately

Setup

Pn88A

2

MECHATROLINK Receive
Error Counter Monitor (for
maintenance, read only)

0 to 65535

0

Immediately

Setup

Pn890 to

Pn89E

4

Command Data Monitor at
Alarm/Warning Occurs
(for maintenance, read only)

0 to

FFFFFFFFH

0

Immediately

Setup

*1

Pn8A0 to

Pn8AE

4

Response Data Monitor at
Alarm/Warning Occurs
(for maintenance, read only)

0 to

FFFFFFFFH

0

Immediately

Setup

*1

Pn900

2

Parameter Bank Number

0 to 16

0

After restart

Setup

*1

Pn901

2

Parameter Bank Member
Number

0 to 15

0

After restart

Setup

*1

Pn902 to

Pn910

2

Parameter Bank Member
Definition

0000H to

08FFH

0

After restart

Setup

*1

Pn920 to

Pn95F

2

Parameter Bank Data (non-
volatile memory save disabled)

0000H to

FFFFH

0

Immediately

Setup

*1

∗1. For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

MECHATROLINK Communications Error Holding Brake Signal Setting

0

Maintain the status set by the BRK_ON or BRK_OFF command when a

MECHATROLINK communications error occurs.

1

Apply the holding brake when a MECHATROLINK communications error occurs.

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

n. † † † †

4th

digit

3rd

digit

2nd

digit

1st

digit

Advertising