3 basic functions settings, 1 servomotor rotation direction – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 90

Advertising
background image

4.3 Basic Functions Settings

4-5

4

Ope

rat

ion

4.3 Basic Functions Settings

4.3.1 Servomotor Rotation Direction

The servomotor rotation direction can be reversed with parameter Pn000.0 without changing the polarity of
the speed/position reference. This causes the rotation direction of the servomotor to change, but the polarity of

the signal, such as encoder output pulses, output from the SERVOPACK does not change. (refer to 4.4.4

Encoder Output Pulses)

The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the ser-

vomotor.

Note: SigmaWin+ trace waveforms are shown in the above table.

Parameter

Forward/

Reverse Ref-

erence

Direction of Motor Rotation and Encoder Output Pulse

Applicable Over-

travel (OT)

Pn000

n.

0

Sets CCW as for-

ward direction.
[Factory setting]

Forward
Reference

P-OT

Reverse
Reference

N-OT

n.

1

Sets CW as for-

ward direction.

(Reverse Rotation

Mode)

Forward
Reference

P-OT

Reverse
Reference

N-OT

CCW

Phase B
advanced

Time

Encoder output pulse

PAO

PBO

Motor speed

Torque reference

Motor speed

+

CW

Phase A
advanced

Time

Encoder output pulse

Motor speed

Torque reference

Motor speed

PAO

PBO

+

PAO

PBO

CW

Phase B
advanced

Encoder output pulse

Motor speed

Torque reference

Motor speed

+

Time

CCW

Phase A
advanced

Encoder output pulse

PAO

PBO

+

Time

Motor speed

Torque reference

Motor speed

Advertising