1 Outline

1.3.3 MECHATROLINK-II Function Specifications

1-8

1.3.3 MECHATROLINK-II Function Specifications

The following table shows the specifications of MECHATROLINK-II.

Function

Specifications

MECHATROLINK-II Com-

munication

Communication Pro-

tocol

MECHATROLINK-II

Station Address

41H to 5FH (Max. number of stations: 30)
Can be selected by the combination of the rotary switch
(SW1) and the DIP switch (SW2).

Baud Rate

10 Mpbs, 4 Mpbs
Can be selected by the DIP switch (SW2).

Transmission Cycle

250

μs, 0.5 ms to 4.0 ms (Multiples of 0.5 ms)

Can be selected by the DIP switch (SW2).

Number of Transmis-

sion Bytes

17 bytes per station or 32 bytes per station
Can be selected by the DIP switch (SW2).

Reference Method

Control Method

Position, speed, or torque control with MECHATROLINK-
II communication

Reference Input

MECHATROLINK-I,MECHATROLINK-II commands
(sequence, motion, data setting/reference, monitoring, or
adjustment)